Haematological validation of a computer-based bone marrow reporting system.

Identifieur interne : 000A26 ( Pmc/Curation ); précédent : 000A25; suivant : 000A27

Haematological validation of a computer-based bone marrow reporting system.

Auteurs : D T Nguyen ; L W Diamond ; J D Cavenagh ; R. Parameswaran ; J A Amess

Source :

RBID : PMC:499937

Abstract

AIMS: To prove the safety and effectiveness of "Professor Belmonte", a knowledge-based system for bone marrow reporting, a formal evaluation of the reports generated by the system was performed. METHODS: Three haematologists (a consultant, a senior registrar, and a junior registrar), none of whom were involved in the development of the software, compared the unedited reports generated by Professor Belmonte with the original bone marrow reports in 785 unselected cases. Each haematologist independently graded the quality of Belmonte's reports using one of four categories: (a) better than the original report (more informative, containing useful information missing in the original report); (b) equivalent to the original report; (c) satisfactory, but missing information that should have been included; and (d) unsatisfactory. RESULTS: The consultant graded 64 reports as more informative than the original, 687 as equivalent to the original, 32 as satisfactory, and two as unsatisfactory. The senior registrar considered 29 reports to be better than the original, 739 to be equivalent to the original, 15 to be satisfactory, and two to be unsatisfactory. The junior registrar found that 88 reports were better than the original, 681 were equivalent to the original, 14 were satisfactory, and two were unsatisfactory. Each judge found two different reports to be unsatisfactory according to their criteria. All 785 reports generated by the computer system received at least two scores of satisfactory or better. CONCLUSIONS: In this representative study, Professor Belmonte generated bone marrow reports that proved to be as accurate as the original reports in a large university hospital. The haematology knowledge contained within the system, the reasoning process, and the function of the software are safe and effective for assisting haematologists in generating high quality bone marrow reports.


Url:
PubMed: 9215118
PubMed Central: 499937

Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:499937

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Haematological validation of a computer-based bone marrow reporting system.</title>
<author>
<name sortKey="Nguyen, D T" sort="Nguyen, D T" uniqKey="Nguyen D" first="D T" last="Nguyen">D T Nguyen</name>
</author>
<author>
<name sortKey="Diamond, L W" sort="Diamond, L W" uniqKey="Diamond L" first="L W" last="Diamond">L W Diamond</name>
</author>
<author>
<name sortKey="Cavenagh, J D" sort="Cavenagh, J D" uniqKey="Cavenagh J" first="J D" last="Cavenagh">J D Cavenagh</name>
</author>
<author>
<name sortKey="Parameswaran, R" sort="Parameswaran, R" uniqKey="Parameswaran R" first="R" last="Parameswaran">R. Parameswaran</name>
</author>
<author>
<name sortKey="Amess, J A" sort="Amess, J A" uniqKey="Amess J" first="J A" last="Amess">J A Amess</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">9215118</idno>
<idno type="pmc">499937</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC499937</idno>
<idno type="RBID">PMC:499937</idno>
<date when="1997">1997</date>
<idno type="wicri:Area/Pmc/Corpus">000A26</idno>
<idno type="wicri:Area/Pmc/Curation">000A26</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Haematological validation of a computer-based bone marrow reporting system.</title>
<author>
<name sortKey="Nguyen, D T" sort="Nguyen, D T" uniqKey="Nguyen D" first="D T" last="Nguyen">D T Nguyen</name>
</author>
<author>
<name sortKey="Diamond, L W" sort="Diamond, L W" uniqKey="Diamond L" first="L W" last="Diamond">L W Diamond</name>
</author>
<author>
<name sortKey="Cavenagh, J D" sort="Cavenagh, J D" uniqKey="Cavenagh J" first="J D" last="Cavenagh">J D Cavenagh</name>
</author>
<author>
<name sortKey="Parameswaran, R" sort="Parameswaran, R" uniqKey="Parameswaran R" first="R" last="Parameswaran">R. Parameswaran</name>
</author>
<author>
<name sortKey="Amess, J A" sort="Amess, J A" uniqKey="Amess J" first="J A" last="Amess">J A Amess</name>
</author>
</analytic>
<series>
<title level="j">Journal of Clinical Pathology</title>
<idno type="ISSN">0021-9746</idno>
<idno type="e-ISSN">1472-4146</idno>
<imprint>
<date when="1997">1997</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>AIMS: To prove the safety and effectiveness of "Professor Belmonte", a knowledge-based system for bone marrow reporting, a formal evaluation of the reports generated by the system was performed. METHODS: Three haematologists (a consultant, a senior registrar, and a junior registrar), none of whom were involved in the development of the software, compared the unedited reports generated by Professor Belmonte with the original bone marrow reports in 785 unselected cases. Each haematologist independently graded the quality of Belmonte's reports using one of four categories: (a) better than the original report (more informative, containing useful information missing in the original report); (b) equivalent to the original report; (c) satisfactory, but missing information that should have been included; and (d) unsatisfactory. RESULTS: The consultant graded 64 reports as more informative than the original, 687 as equivalent to the original, 32 as satisfactory, and two as unsatisfactory. The senior registrar considered 29 reports to be better than the original, 739 to be equivalent to the original, 15 to be satisfactory, and two to be unsatisfactory. The junior registrar found that 88 reports were better than the original, 681 were equivalent to the original, 14 were satisfactory, and two were unsatisfactory. Each judge found two different reports to be unsatisfactory according to their criteria. All 785 reports generated by the computer system received at least two scores of satisfactory or better. CONCLUSIONS: In this representative study, Professor Belmonte generated bone marrow reports that proved to be as accurate as the original reports in a large university hospital. The haematology knowledge contained within the system, the reasoning process, and the function of the software are safe and effective for assisting haematologists in generating high quality bone marrow reports.</p>
</div>
</front>
</TEI>
<pmc article-type="research-article">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">J Clin Pathol</journal-id>
<journal-title>Journal of Clinical Pathology</journal-title>
<issn pub-type="ppub">0021-9746</issn>
<issn pub-type="epub">1472-4146</issn>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">9215118</article-id>
<article-id pub-id-type="pmc">499937</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Research Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Haematological validation of a computer-based bone marrow reporting system.</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Nguyen</surname>
<given-names>D T</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Diamond</surname>
<given-names>L W</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Cavenagh</surname>
<given-names>J D</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Parameswaran</surname>
<given-names>R</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Amess</surname>
<given-names>J A</given-names>
</name>
</contrib>
</contrib-group>
<aff>Department of Haematology, St Bartholomew's Hospital, London, United Kingdom.</aff>
<pub-date pub-type="ppub">
<month>5</month>
<year>1997</year>
</pub-date>
<volume>50</volume>
<issue>5</issue>
<fpage>375</fpage>
<lpage>378</lpage>
<abstract>
<p>AIMS: To prove the safety and effectiveness of "Professor Belmonte", a knowledge-based system for bone marrow reporting, a formal evaluation of the reports generated by the system was performed. METHODS: Three haematologists (a consultant, a senior registrar, and a junior registrar), none of whom were involved in the development of the software, compared the unedited reports generated by Professor Belmonte with the original bone marrow reports in 785 unselected cases. Each haematologist independently graded the quality of Belmonte's reports using one of four categories: (a) better than the original report (more informative, containing useful information missing in the original report); (b) equivalent to the original report; (c) satisfactory, but missing information that should have been included; and (d) unsatisfactory. RESULTS: The consultant graded 64 reports as more informative than the original, 687 as equivalent to the original, 32 as satisfactory, and two as unsatisfactory. The senior registrar considered 29 reports to be better than the original, 739 to be equivalent to the original, 15 to be satisfactory, and two to be unsatisfactory. The junior registrar found that 88 reports were better than the original, 681 were equivalent to the original, 14 were satisfactory, and two were unsatisfactory. Each judge found two different reports to be unsatisfactory according to their criteria. All 785 reports generated by the computer system received at least two scores of satisfactory or better. CONCLUSIONS: In this representative study, Professor Belmonte generated bone marrow reports that proved to be as accurate as the original reports in a large university hospital. The haematology knowledge contained within the system, the reasoning process, and the function of the software are safe and effective for assisting haematologists in generating high quality bone marrow reports.</p>
</abstract>
</article-meta>
</front>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Musique/explor/OperaV1/Data/Pmc/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000A26 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Curation/biblio.hfd -nk 000A26 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Musique
   |area=    OperaV1
   |flux=    Pmc
   |étape=   Curation
   |type=    RBID
   |clé=     PMC:499937
   |texte=   Haematological validation of a computer-based bone marrow reporting system.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Curation/RBID.i   -Sk "pubmed:9215118" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a OperaV1 

Wicri

This area was generated with Dilib version V0.6.21.
Data generation: Thu Apr 14 14:59:05 2016. Site generation: Thu Oct 8 06:48:41 2020