Supplemental data of dependence of objective room acoustical parameters on source and receiver positions at field measurement

Identifieur interne : 000398 ( PascalFrancis/Corpus ); précédent : 000397; suivant : 000399

Supplemental data of dependence of objective room acoustical parameters on source and receiver positions at field measurement

Auteurs : Takayuki Hidaka

Source :

RBID : Pascal:05-0264873

Descripteurs français

English descriptors

Abstract

Representative values of acoustical parameters in rooms for music performance are obtained from measurements in many halls. Discussed are the effects of source locations and positions of receivers on the results. The parameters studied are reverberation time RT, early decay time EDT, strength G, clarity C80, and interaural-cross-correlation coefficient IACC, which were measured using identical procedures, and where possible, according to international standard ISO 3382. Separate ranges and positions are suggested for symphony halls, chamber music halls and opera houses. It is indicated that the minimum number of positions given in ISO 3382 should be exceeded when measuring some parameters.

Notice en format standard (ISO 2709)

Pour connaître la documentation sur le format Inist Standard.

pA  
A01 01  1    @0 1346-3969
A03   1    @0 Acoust. sci. technol.
A05       @2 26
A06       @2 2
A08 01  1  ENG  @1 Supplemental data of dependence of objective room acoustical parameters on source and receiver positions at field measurement
A11 01  1    @1 HIDAKA (Takayuki)
A14 01      @1 Takenaka R&D Institute, 1-5-1 @2 Otsuka, Inzai, 270-1395 @3 JPN @Z 1 aut.
A20       @1 128-135
A21       @1 2005
A23 01      @0 ENG
A43 01      @1 INIST @2 18937 @5 354000126428240050
A44       @0 0000 @1 © 2005 INIST-CNRS. All rights reserved.
A45       @0 11 ref.
A47 01  1    @0 05-0264873
A60       @1 P @2 C
A61       @0 A
A64 01  1    @0 Acoustical science and technology
A66 01      @0 JPN
C01 01    ENG  @0 Representative values of acoustical parameters in rooms for music performance are obtained from measurements in many halls. Discussed are the effects of source locations and positions of receivers on the results. The parameters studied are reverberation time RT, early decay time EDT, strength G, clarity C80, and interaural-cross-correlation coefficient IACC, which were measured using identical procedures, and where possible, according to international standard ISO 3382. Separate ranges and positions are suggested for symphony halls, chamber music halls and opera houses. It is indicated that the minimum number of positions given in ISO 3382 should be exceeded when measuring some parameters.
C02 01  X    @0 001B40C55
C03 01  X  FRE  @0 Acoustique salle @5 06
C03 01  X  ENG  @0 Room acoustics @5 06
C03 01  X  SPA  @0 Acústica sala @5 06
C03 02  X  FRE  @0 Acoustique musicale @5 07
C03 02  X  ENG  @0 Musical acoustics @5 07
C03 02  X  SPA  @0 Acústica musical @5 07
C03 03  X  FRE  @0 Localisation @5 08
C03 03  X  ENG  @0 Localization @5 08
C03 03  X  SPA  @0 Localización @5 08
C03 04  X  FRE  @0 Réverbération acoustique @5 09
C03 04  X  ENG  @0 Acoustic reverberation @5 09
C03 04  X  SPA  @0 Reverberación acústica @5 09
C03 05  X  FRE  @0 Audition binaurale @5 10
C03 05  X  ENG  @0 Binaural hearing @5 10
C03 05  X  SPA  @0 Audición binaural @5 10
C03 06  X  FRE  @0 Norme @5 11
C03 06  X  ENG  @0 Standards @5 11
C03 06  X  SPA  @0 Norma @5 11
C03 07  X  FRE  @0 Salle concert @5 12
C03 07  X  ENG  @0 Concert hall @5 12
C03 07  X  SPA  @0 Sala concierto @5 12
C03 08  X  FRE  @0 Temps descente @5 15
C03 08  X  ENG  @0 Decay time @5 15
C03 08  X  SPA  @0 Tiempo bajada @5 15
C03 09  X  FRE  @0 Temps interauriculaire @5 16
C03 09  X  ENG  @0 Interaural time @5 16
C03 09  X  SPA  @0 Tiempo interauricular @5 16
C03 10  X  FRE  @0 Temps réverbération @5 23
C03 10  X  ENG  @0 Reverberation time @5 23
C03 10  X  SPA  @0 Tiempo reverberación @5 23
C03 11  X  FRE  @0 Corrélation croisée @5 24
C03 11  X  ENG  @0 Cross correlation @5 24
C03 11  X  SPA  @0 Correlación cruzada @5 24
C03 12  X  FRE  @0 Analyse objective @5 33
C03 12  X  ENG  @0 Objective analysis @5 33
C03 12  X  SPA  @0 Análisis objetivos @5 33
C03 13  X  FRE  @0 Mesure position @5 34
C03 13  X  ENG  @0 Position measurement @5 34
C03 13  X  SPA  @0 Medición posición @5 34
N21       @1 185
N44 01      @1 OTO
N82       @1 OTO
pR  
A30 01  1  ENG  @1 Special issue on Room Acoulstics in honour of RADS 2004. Symposium @3 Island of Awaji JPN @4 2004-04-11

Format Inist (serveur)

NO : PASCAL 05-0264873 INIST
ET : Supplemental data of dependence of objective room acoustical parameters on source and receiver positions at field measurement
AU : HIDAKA (Takayuki)
AF : Takenaka R&D Institute, 1-5-1/Otsuka, Inzai, 270-1395/Japon (1 aut.)
DT : Publication en série; Congrès; Niveau analytique
SO : Acoustical science and technology; ISSN 1346-3969; Japon; Da. 2005; Vol. 26; No. 2; Pp. 128-135; Bibl. 11 ref.
LA : Anglais
EA : Representative values of acoustical parameters in rooms for music performance are obtained from measurements in many halls. Discussed are the effects of source locations and positions of receivers on the results. The parameters studied are reverberation time RT, early decay time EDT, strength G, clarity C80, and interaural-cross-correlation coefficient IACC, which were measured using identical procedures, and where possible, according to international standard ISO 3382. Separate ranges and positions are suggested for symphony halls, chamber music halls and opera houses. It is indicated that the minimum number of positions given in ISO 3382 should be exceeded when measuring some parameters.
CC : 001B40C55
FD : Acoustique salle; Acoustique musicale; Localisation; Réverbération acoustique; Audition binaurale; Norme; Salle concert; Temps descente; Temps interauriculaire; Temps réverbération; Corrélation croisée; Analyse objective; Mesure position
ED : Room acoustics; Musical acoustics; Localization; Acoustic reverberation; Binaural hearing; Standards; Concert hall; Decay time; Interaural time; Reverberation time; Cross correlation; Objective analysis; Position measurement
SD : Acústica sala; Acústica musical; Localización; Reverberación acústica; Audición binaural; Norma; Sala concierto; Tiempo bajada; Tiempo interauricular; Tiempo reverberación; Correlación cruzada; Análisis objetivos; Medición posición
LO : INIST-18937.354000126428240050
ID : 05-0264873

Links to Exploration step

Pascal:05-0264873

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">Supplemental data of dependence of objective room acoustical parameters on source and receiver positions at field measurement</title>
<author>
<name sortKey="Hidaka, Takayuki" sort="Hidaka, Takayuki" uniqKey="Hidaka T" first="Takayuki" last="Hidaka">Takayuki Hidaka</name>
<affiliation>
<inist:fA14 i1="01">
<s1>Takenaka R&D Institute, 1-5-1</s1>
<s2>Otsuka, Inzai, 270-1395</s2>
<s3>JPN</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">05-0264873</idno>
<date when="2005">2005</date>
<idno type="stanalyst">PASCAL 05-0264873 INIST</idno>
<idno type="RBID">Pascal:05-0264873</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000398</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">Supplemental data of dependence of objective room acoustical parameters on source and receiver positions at field measurement</title>
<author>
<name sortKey="Hidaka, Takayuki" sort="Hidaka, Takayuki" uniqKey="Hidaka T" first="Takayuki" last="Hidaka">Takayuki Hidaka</name>
<affiliation>
<inist:fA14 i1="01">
<s1>Takenaka R&D Institute, 1-5-1</s1>
<s2>Otsuka, Inzai, 270-1395</s2>
<s3>JPN</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</analytic>
<series>
<title level="j" type="main">Acoustical science and technology</title>
<title level="j" type="abbreviated">Acoust. sci. technol.</title>
<idno type="ISSN">1346-3969</idno>
<imprint>
<date when="2005">2005</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">Acoustical science and technology</title>
<title level="j" type="abbreviated">Acoust. sci. technol.</title>
<idno type="ISSN">1346-3969</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Acoustic reverberation</term>
<term>Binaural hearing</term>
<term>Concert hall</term>
<term>Cross correlation</term>
<term>Decay time</term>
<term>Interaural time</term>
<term>Localization</term>
<term>Musical acoustics</term>
<term>Objective analysis</term>
<term>Position measurement</term>
<term>Reverberation time</term>
<term>Room acoustics</term>
<term>Standards</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Acoustique salle</term>
<term>Acoustique musicale</term>
<term>Localisation</term>
<term>Réverbération acoustique</term>
<term>Audition binaurale</term>
<term>Norme</term>
<term>Salle concert</term>
<term>Temps descente</term>
<term>Temps interauriculaire</term>
<term>Temps réverbération</term>
<term>Corrélation croisée</term>
<term>Analyse objective</term>
<term>Mesure position</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Representative values of acoustical parameters in rooms for music performance are obtained from measurements in many halls. Discussed are the effects of source locations and positions of receivers on the results. The parameters studied are reverberation time RT, early decay time EDT, strength G, clarity C
<sub>80</sub>
, and interaural-cross-correlation coefficient IACC, which were measured using identical procedures, and where possible, according to international standard ISO 3382. Separate ranges and positions are suggested for symphony halls, chamber music halls and opera houses. It is indicated that the minimum number of positions given in ISO 3382 should be exceeded when measuring some parameters.</div>
</front>
</TEI>
<inist>
<standard h6="B">
<pA>
<fA01 i1="01" i2="1">
<s0>1346-3969</s0>
</fA01>
<fA03 i2="1">
<s0>Acoust. sci. technol.</s0>
</fA03>
<fA05>
<s2>26</s2>
</fA05>
<fA06>
<s2>2</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG">
<s1>Supplemental data of dependence of objective room acoustical parameters on source and receiver positions at field measurement</s1>
</fA08>
<fA11 i1="01" i2="1">
<s1>HIDAKA (Takayuki)</s1>
</fA11>
<fA14 i1="01">
<s1>Takenaka R&D Institute, 1-5-1</s1>
<s2>Otsuka, Inzai, 270-1395</s2>
<s3>JPN</s3>
<sZ>1 aut.</sZ>
</fA14>
<fA20>
<s1>128-135</s1>
</fA20>
<fA21>
<s1>2005</s1>
</fA21>
<fA23 i1="01">
<s0>ENG</s0>
</fA23>
<fA43 i1="01">
<s1>INIST</s1>
<s2>18937</s2>
<s5>354000126428240050</s5>
</fA43>
<fA44>
<s0>0000</s0>
<s1>© 2005 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45>
<s0>11 ref.</s0>
</fA45>
<fA47 i1="01" i2="1">
<s0>05-0264873</s0>
</fA47>
<fA60>
<s1>P</s1>
<s2>C</s2>
</fA60>
<fA61>
<s0>A</s0>
</fA61>
<fA64 i1="01" i2="1">
<s0>Acoustical science and technology</s0>
</fA64>
<fA66 i1="01">
<s0>JPN</s0>
</fA66>
<fC01 i1="01" l="ENG">
<s0>Representative values of acoustical parameters in rooms for music performance are obtained from measurements in many halls. Discussed are the effects of source locations and positions of receivers on the results. The parameters studied are reverberation time RT, early decay time EDT, strength G, clarity C
<sub>80</sub>
, and interaural-cross-correlation coefficient IACC, which were measured using identical procedures, and where possible, according to international standard ISO 3382. Separate ranges and positions are suggested for symphony halls, chamber music halls and opera houses. It is indicated that the minimum number of positions given in ISO 3382 should be exceeded when measuring some parameters.</s0>
</fC01>
<fC02 i1="01" i2="X">
<s0>001B40C55</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE">
<s0>Acoustique salle</s0>
<s5>06</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG">
<s0>Room acoustics</s0>
<s5>06</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA">
<s0>Acústica sala</s0>
<s5>06</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE">
<s0>Acoustique musicale</s0>
<s5>07</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG">
<s0>Musical acoustics</s0>
<s5>07</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA">
<s0>Acústica musical</s0>
<s5>07</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE">
<s0>Localisation</s0>
<s5>08</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG">
<s0>Localization</s0>
<s5>08</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA">
<s0>Localización</s0>
<s5>08</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE">
<s0>Réverbération acoustique</s0>
<s5>09</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG">
<s0>Acoustic reverberation</s0>
<s5>09</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA">
<s0>Reverberación acústica</s0>
<s5>09</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE">
<s0>Audition binaurale</s0>
<s5>10</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG">
<s0>Binaural hearing</s0>
<s5>10</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA">
<s0>Audición binaural</s0>
<s5>10</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE">
<s0>Norme</s0>
<s5>11</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG">
<s0>Standards</s0>
<s5>11</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA">
<s0>Norma</s0>
<s5>11</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE">
<s0>Salle concert</s0>
<s5>12</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG">
<s0>Concert hall</s0>
<s5>12</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA">
<s0>Sala concierto</s0>
<s5>12</s5>
</fC03>
<fC03 i1="08" i2="X" l="FRE">
<s0>Temps descente</s0>
<s5>15</s5>
</fC03>
<fC03 i1="08" i2="X" l="ENG">
<s0>Decay time</s0>
<s5>15</s5>
</fC03>
<fC03 i1="08" i2="X" l="SPA">
<s0>Tiempo bajada</s0>
<s5>15</s5>
</fC03>
<fC03 i1="09" i2="X" l="FRE">
<s0>Temps interauriculaire</s0>
<s5>16</s5>
</fC03>
<fC03 i1="09" i2="X" l="ENG">
<s0>Interaural time</s0>
<s5>16</s5>
</fC03>
<fC03 i1="09" i2="X" l="SPA">
<s0>Tiempo interauricular</s0>
<s5>16</s5>
</fC03>
<fC03 i1="10" i2="X" l="FRE">
<s0>Temps réverbération</s0>
<s5>23</s5>
</fC03>
<fC03 i1="10" i2="X" l="ENG">
<s0>Reverberation time</s0>
<s5>23</s5>
</fC03>
<fC03 i1="10" i2="X" l="SPA">
<s0>Tiempo reverberación</s0>
<s5>23</s5>
</fC03>
<fC03 i1="11" i2="X" l="FRE">
<s0>Corrélation croisée</s0>
<s5>24</s5>
</fC03>
<fC03 i1="11" i2="X" l="ENG">
<s0>Cross correlation</s0>
<s5>24</s5>
</fC03>
<fC03 i1="11" i2="X" l="SPA">
<s0>Correlación cruzada</s0>
<s5>24</s5>
</fC03>
<fC03 i1="12" i2="X" l="FRE">
<s0>Analyse objective</s0>
<s5>33</s5>
</fC03>
<fC03 i1="12" i2="X" l="ENG">
<s0>Objective analysis</s0>
<s5>33</s5>
</fC03>
<fC03 i1="12" i2="X" l="SPA">
<s0>Análisis objetivos</s0>
<s5>33</s5>
</fC03>
<fC03 i1="13" i2="X" l="FRE">
<s0>Mesure position</s0>
<s5>34</s5>
</fC03>
<fC03 i1="13" i2="X" l="ENG">
<s0>Position measurement</s0>
<s5>34</s5>
</fC03>
<fC03 i1="13" i2="X" l="SPA">
<s0>Medición posición</s0>
<s5>34</s5>
</fC03>
<fN21>
<s1>185</s1>
</fN21>
<fN44 i1="01">
<s1>OTO</s1>
</fN44>
<fN82>
<s1>OTO</s1>
</fN82>
</pA>
<pR>
<fA30 i1="01" i2="1" l="ENG">
<s1>Special issue on Room Acoulstics in honour of RADS 2004. Symposium</s1>
<s3>Island of Awaji JPN</s3>
<s4>2004-04-11</s4>
</fA30>
</pR>
</standard>
<server>
<NO>PASCAL 05-0264873 INIST</NO>
<ET>Supplemental data of dependence of objective room acoustical parameters on source and receiver positions at field measurement</ET>
<AU>HIDAKA (Takayuki)</AU>
<AF>Takenaka R&D Institute, 1-5-1/Otsuka, Inzai, 270-1395/Japon (1 aut.)</AF>
<DT>Publication en série; Congrès; Niveau analytique</DT>
<SO>Acoustical science and technology; ISSN 1346-3969; Japon; Da. 2005; Vol. 26; No. 2; Pp. 128-135; Bibl. 11 ref.</SO>
<LA>Anglais</LA>
<EA>Representative values of acoustical parameters in rooms for music performance are obtained from measurements in many halls. Discussed are the effects of source locations and positions of receivers on the results. The parameters studied are reverberation time RT, early decay time EDT, strength G, clarity C
<sub>80</sub>
, and interaural-cross-correlation coefficient IACC, which were measured using identical procedures, and where possible, according to international standard ISO 3382. Separate ranges and positions are suggested for symphony halls, chamber music halls and opera houses. It is indicated that the minimum number of positions given in ISO 3382 should be exceeded when measuring some parameters.</EA>
<CC>001B40C55</CC>
<FD>Acoustique salle; Acoustique musicale; Localisation; Réverbération acoustique; Audition binaurale; Norme; Salle concert; Temps descente; Temps interauriculaire; Temps réverbération; Corrélation croisée; Analyse objective; Mesure position</FD>
<ED>Room acoustics; Musical acoustics; Localization; Acoustic reverberation; Binaural hearing; Standards; Concert hall; Decay time; Interaural time; Reverberation time; Cross correlation; Objective analysis; Position measurement</ED>
<SD>Acústica sala; Acústica musical; Localización; Reverberación acústica; Audición binaural; Norma; Sala concierto; Tiempo bajada; Tiempo interauricular; Tiempo reverberación; Correlación cruzada; Análisis objetivos; Medición posición</SD>
<LO>INIST-18937.354000126428240050</LO>
<ID>05-0264873</ID>
</server>
</inist>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Musique/explor/OperaV1/Data/PascalFrancis/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000398 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Corpus/biblio.hfd -nk 000398 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Musique
   |area=    OperaV1
   |flux=    PascalFrancis
   |étape=   Corpus
   |type=    RBID
   |clé=     Pascal:05-0264873
   |texte=   Supplemental data of dependence of objective room acoustical parameters on source and receiver positions at field measurement
}}

Wicri

This area was generated with Dilib version V0.6.21.
Data generation: Thu Apr 14 14:59:05 2016. Site generation: Thu Oct 8 06:48:41 2020