Reduced pole placement method for cascaded frequency control via dispersed pulse inverters

Identifieur interne : 000153 ( Main/Exploration ); précédent : 000152; suivant : 000154

Reduced pole placement method for cascaded frequency control via dispersed pulse inverters

Auteurs : J. Sachau [Luxembourg (pays)]

Source :

RBID : ISTEX:FFC3FBD09EB6B1B654B9791E661D385B62F10E4E

Mots-clés :

Abstract

For modular power systems, structures with parallel power inverters are favourable in view of both easy expandability and supply security. The inverters' embedded controllers are implementing voltage and frequency droops and the superimposed frequency control is coupled via fieldbus. This is a case where a superimposed control is acting via one or more locally dispersed subimposed control‐loops. As the states of the subimposed loops are inaccessible, their feedback is no longer viable. The method of reduced pole placement allows reformulation of the design task as complete state feedback without employing a feedback of the single virtual state that just globally describes the one or more subimposed systems. Results are presented for a robust grid frequency controller acting via dispersed pulse inverters. Copyright © 2005 John Wiley & Sons, Ltd.


Url:
DOI: 10.1002/etep.41


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Reduced pole placement method for cascaded frequency control via dispersed pulse inverters</title>
<author>
<name sortKey="Sachau, J" sort="Sachau, J" uniqKey="Sachau J" first="J." last="Sachau">J. Sachau</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:FFC3FBD09EB6B1B654B9791E661D385B62F10E4E</idno>
<date when="2005" year="2005">2005</date>
<idno type="doi">10.1002/etep.41</idno>
<idno type="url">https://api.istex.fr/document/FFC3FBD09EB6B1B654B9791E661D385B62F10E4E/fulltext/pdf</idno>
<idno type="wicri:Area/Main/Corpus">000524</idno>
<idno type="wicri:explorRef" wicri:stream="Main" wicri:step="Corpus" wicri:corpus="ISTEX">000524</idno>
<idno type="wicri:Area/Main/Curation">000524</idno>
<idno type="wicri:Area/Main/Exploration">000153</idno>
<idno type="wicri:explorRef" wicri:stream="Main" wicri:step="Exploration">000153</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Reduced pole placement method for cascaded frequency control via dispersed pulse inverters</title>
<author>
<name sortKey="Sachau, J" sort="Sachau, J" uniqKey="Sachau J" first="J." last="Sachau">J. Sachau</name>
<affiliation wicri:level="4">
<country xml:lang="fr">Luxembourg (pays)</country>
<wicri:regionArea>University of Luxembourg, 6 rue Richard Coudenhove‐Kalergi</wicri:regionArea>
<orgName type="university">Université du Luxembourg</orgName>
<placeName>
<settlement type="city">Luxembourg</settlement>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">European Transactions on Electrical Power</title>
<title level="j" type="abbrev">Euro. Trans. Electr. Power</title>
<idno type="ISSN">1430-144X</idno>
<idno type="eISSN">1546-3109</idno>
<imprint>
<publisher>John Wiley & Sons, Ltd.</publisher>
<pubPlace>Chichester, UK</pubPlace>
<date type="published" when="2005-07">2005-07</date>
<biblScope unit="vol">15</biblScope>
<biblScope unit="issue">4</biblScope>
<biblScope unit="page" from="343">343</biblScope>
<biblScope unit="page" to="350">350</biblScope>
</imprint>
<idno type="ISSN">1430-144X</idno>
</series>
<idno type="istex">FFC3FBD09EB6B1B654B9791E661D385B62F10E4E</idno>
<idno type="DOI">10.1002/etep.41</idno>
<idno type="ArticleID">ETEP41</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">1430-144X</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>decentral control</term>
<term>modular power systems</term>
<term>pulse inverter</term>
<term>reduced pole placement</term>
</keywords>
</textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">For modular power systems, structures with parallel power inverters are favourable in view of both easy expandability and supply security. The inverters' embedded controllers are implementing voltage and frequency droops and the superimposed frequency control is coupled via fieldbus. This is a case where a superimposed control is acting via one or more locally dispersed subimposed control‐loops. As the states of the subimposed loops are inaccessible, their feedback is no longer viable. The method of reduced pole placement allows reformulation of the design task as complete state feedback without employing a feedback of the single virtual state that just globally describes the one or more subimposed systems. Results are presented for a robust grid frequency controller acting via dispersed pulse inverters. Copyright © 2005 John Wiley & Sons, Ltd.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Luxembourg (pays)</li>
</country>
<settlement>
<li>Luxembourg</li>
</settlement>
<orgName>
<li>Université du Luxembourg</li>
</orgName>
</list>
<tree>
<country name="Luxembourg (pays)">
<noRegion>
<name sortKey="Sachau, J" sort="Sachau, J" uniqKey="Sachau J" first="J." last="Sachau">J. Sachau</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Informatique/corpus/FieldbusV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000153 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Informatique
   |area=    FieldbusV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:FFC3FBD09EB6B1B654B9791E661D385B62F10E4E
   |texte=   Reduced pole placement method for cascaded frequency control via dispersed pulse inverters
}}

Wicri

This area was generated with Dilib version V0.6.29.
Data generation: Thu May 25 22:29:54 2017. Site generation: Wed Jul 19 17:31:17 2017